Selecting AW20-D: review the full part number and your system conditions when considering this Air preparation record. Share Body Size, Backflow Function, Thread, Port Size, Options, Set pressure, Bowl, Drain Guide, Exhaust Mechanism, Flow Direction, Drain Cock w/Barb Fitting, Pressure Units, the required quantity and your application notes with Pnoneks. Final compatibility and lead time are confirmed during quotation.
The essentials for selection.
- Manufacturer
- SMC
- Series
- AW20-D
- Product group
- Air preparation
- Function
- Compressed Air Filter Regulators
- Applications
- Suitability is evaluated against technical specifications and application conditions.
- Selection parameters
- Body Size, Backflow Function, Thread, Port Size, Options, Set pressure, Bowl, Drain Guide, Exhaust Mechanism, Flow Direction, Drain Cock w/Barb Fitting, Pressure Units
Exact dimensions, operating ranges and compatibility depend on the full part number. Review the relevant SMC documentation and application conditions for technical selection.
Features and model options
Technical descriptions and values below are preserved in the manufacturer’s original language. Options describe alternatives within the series; not every combination is valid. We will verify the full part number when quoting.
| Parameter | Options / values |
|---|---|
| Body Size | 20 · 30 · 40 · 60 |
| Backflow Function | None · K (w/Backflow Function) |
| Thread | Rc · N (NPT) · F (G) |
| Port Size | 01 (1/8) · 02 (1/4) · 03 (3/8) · 04 (1/2) · 06 (3/4) · 10 (1) |
| Options | w/o Mounting Option · B (With Bracket) · H (w/Set Nut, for Panel Mount) · C [Float Style Auto Drain (N.C.)] · D [Float Style Auto Drain (N.O.)] · E (Square embedded type pressure gauge [with limit indicator]) · E1 (Output: NPN output / Electrical entry: Wiring bottom entry) · E2 (Output: NPN output / Electrical entry: Wiring top entry) · E3 (Output: PNP output / Electrical entry: Wiring bottom entry) · E4 (Output: PNP output / Electrical entry: Wiring top entry) · G (Round Pressure Gauge w/Limit Indicator) · M [Round type pressure gauge (with colour zone)] · BC [Bracket + Float Type Auto Drain (N.C.)] · BCE (w/Bracket + Float Type Auto Drain [N.C.] + Square embedded type pressure gauge [with limit indicator]) · BCE1 (w/Bracket + Float Type Auto Drain [N.C.] + Output: NPN output / Electrical entry: Wiring bottom entry) · BCE2 (w/Bracket + Float Type Auto Drain [N.C.] + Output: NPN output / Electrical entry: Wiring top entry) · BCE3 (w/Bracket + Float Type Auto Drain [N.C.] + Output: PNP output / Electrical entry: Wiring bottom entry) · BCE4 (w/Bracket + Float Type Auto Drain [N.C.] + Output: PNP output / Electrical entry: Wiring top entry) · BCG (w/Bracket + Float Type Auto Drain [N.C.] + Round Pressure Gauge w/Limit Indicator) · BCM (w/Bracket + Float Type Auto Drain [N.C.] + Round type pressure gauge [with colour zone]) · BD [Bracket + Float Type Auto Drain (N.O.)] · BDE (w/Bracket + Float Type Auto Drain [N.O.] + Square embedded type pressure gauge [with limit indicator]) · BDE1 (w/Bracket + Float Type Auto Drain [N.O.] + Output: NPN output / Electrical entry: Wiring bottom entry) · BDE2 (w/Bracket + Float Type Auto Drain [N.O.] + Output: NPN output / Electrical entry: Wiring top entry) · BDE3 (w/Bracket + Float Type Auto Drain [N.O.] + Output: PNP output / Electrical entry: Wiring bottom entry) · BDE4 (w/Bracket + Float Type Auto Drain [N.O.] + Output: PNP output / Electrical entry: Wiring top entry) · BDG (w/Bracket + Float Type Auto Drain [N.O.] + Round Pressure Gauge w/Limit Indicator) · BE (w/Bracket + Square embedded type pressure gauge [with limit indicator]) · BE1 (w/Bracket + Output: NPN output / Electrical entry: Wiring bottom entry) · BE2 (w/Bracket + Output: NPN output / Electrical entry: Wiring top entry) · BE3 (w/Bracket + Output: PNP output / Electrical entry: Wiring bottom entry) · BE4 (w/Bracket + Output: PNP output / Electrical entry: Wiring top entry) · BG (Bracket + Round type pressure gauge [with limit indicator]) · BM (Bracket + Round Pressure Gauge [with Colour Zone]) · CE (Float Type Auto Drain [N.C.] + Square embedded type pressure gauge [with limit indicator]) · CE1 (Float Type Auto Drain [N.C.] + Output: NPN output / Electrical entry: Wiring bottom entry) · CE1H (Float Type Auto Drain [N.C.] + Output: NPN output / Electrical entry: Wiring bottom entry + w/Set Nut, for Panel Mount) · CE2 (Float Type Auto Drain [N.C.] + Output: NPN output / Electrical entry: Wiring top entry) · CE2H (Float Type Auto Drain [N.C.] + Output: NPN output / Electrical entry: Wiring top entry + w/Set Nut, for Panel Mount) · CE3 (Float Type Auto Drain [N.C.] + Output: PNP output / Electrical entry: Wiring bottom entry) · CE3H (Float Type Auto Drain [N.C.] + Output: PNP output / Electrical entry: Wiring bottom entry + w/Set Nut, for Panel Mount) · CE4 (Float Type Auto Drain [N.C.] + Output: PNP output / Electrical entry: Wiring top entry) · CE4H (Float Type Auto Drain [N.C.] + Output: PNP output / Electrical entry: Wiring top entry + w/Set Nut, for Panel Mount) · CEH (Float Type Auto Drain [N.C.] + Square embedded type pressure gauge [with limit indicator] + w/Set Nut, for Panel Mount) · CG (Float Type Auto Drain [N.C.] + Round type pressure gauge [with limit indicator]) · CGH (Float Type Auto Drain [N.C.] + Round type pressure gauge [with limit indicator] + Panel Mount w/Set Nut) · CH (Float Type Auto Drain [N.C.] + w/Set Nut, for Panel Mount) · CHM (Float Type Auto Drain [N.C.] + w/Set Nut, for Panel Mount + Round type pressure gauge [with colour zone]) · CM (Float Type Auto Drain [N.C.] + Round type pressure gauge [with colour zone]) · DE (Float Type Auto Drain [N.O.] + Square embedded type pressure gauge [with limit indicator]) · DE1 (Float Type Auto Drain [N.O.] + Output: NPN output / Electrical entry: Wiring bottom entry) · DE1H (Float Type Auto Drain [N.O.] + Output: NPN output / Electrical entry: Wiring bottom entry + w/Set Nut, for Panel Mount) · DE2 (Float Type Auto Drain [N.O.] + Output: NPN output / Electrical entry: Wiring top entry) · DE2H (Float Type Auto Drain [N.O.] + Output: NPN output / Electrical entry: Wiring top entry + w/Set Nut, for Panel Mount) · DE3 (Float Type Auto Drain [N.O.] + Output: PNP output / Electrical entry: Wiring bottom entry) · DE3H (Float Type Auto Drain [N.O.] + Output: PNP output / Electrical entry: Wiring bottom entry + w/Set Nut, for Panel Mount) · DE4 (Float Type Auto Drain [N.O.] + Output: PNP output / Electrical entry: Wiring top entry) · DE4H (Float Type Auto Drain [N.O.] + Output: PNP output / Electrical entry: Wiring top entry + w/Set Nut, for Panel Mount) · DEH (Float Type Auto Drain [N.O.] + Square embedded type pressure gauge [with limit indicator] + w/Set Nut, for Panel Mount) · DG (Float Type Auto Drain [N.O.] + Round type pressure gauge [with limit indicator]) · DGH (Float Type Auto Drain [N.O.] + Round type pressure gauge [with limit indicator] + Panel Mount w/Set Nut) · DH (Float Type Auto Drain [N.O.] + Panel Mount w/Set Nut) · DHM (Float Type Auto Drain [N.O.] + Panel Mount w/Set Nut + Round Pressure Gauge [with Colour Zone]) · DM (Float Type Auto Drain [N.O.] + Round type pressure gauge [with colour zone]) · E1H (Output: NPN output / Electrical entry: Wiring bottom entry + w/Set Nut, for Panel Mount) · E2H (Output: NPN output / Electrical entry: Wiring top entry + w/Set Nut, for Panel Mount) · E3H (Output: PNP output / Electrical entry: Wiring bottom entry + w/Set Nut, for Panel Mount) · E4H (Output: PNP output / Electrical entry: Wiring top entry + w/Set Nut, for Panel Mount) · EH (Square embedded type pressure gauge [with limit indicator] + w/Set Nut, for Panel Mount) · GH (Round type pressure gauge [with limit indicator] + w/Set Nut, for Panel Mount) · HM (w/Set Nut, for Panel Mount + Round type pressure gauge [with colour zone]) |
| Set pressure | 0.05 to 0.85 MPa Setting · 1 (0.02 to 0.2 MPa setting) |
| Bowl | Polycarbonate Bowl · 2 (Metal Bowl) · 6 (Nylon Bowl) · 8 (Metal Bowl w/Level Gauge) · C (Bowl Guard) · 6C [Bowl Guard (Nylon Bowl)] |
| Drain Guide | Standard · J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 30, 40) |
| Exhaust Mechanism | Relieving · N (Non-relieving) |
| Flow Direction | Left to Right · R (Right to Left) |
| Drain Cock w/Barb Fitting | None · W (Drain Cock w/Barb Fitting) |
| Pressure Units | Standard (Name Plate, Caution Plate for Bowl, and Pressure Gauge: MPa) · Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F) · ZA (Digital Pressure Switch: With Unit Conversion Function) |