SMC Authorized Reseller
Monday–Friday · 09:00–18:000850 811 86 07
SMCZK2*A Vacuum Unit. Ejector System/ Vacuum Pump System - ZK2*ASeries image. Appearance may vary by model and options.
Vacuum technology

ZK2*A

Catalogue variant 5

Vacuum Unit. Ejector System/ Vacuum Pump System - ZK2*A

Explore the features, model options and technical documentation for ZK2*A. Contact Pnoneks to select the full part number for your application.

SMC ·Vacuum Ejectors

Request a quote for your application.

Share your part number and quantity so we can confirm pricing and lead time.

Your message opens in WhatsApp. You can review and edit it before sending.

Selecting ZK2*A

Selecting ZK2*A: review the full part number and your system conditions when considering this Vacuum technology record. Share Stations, System/Port, Exhaust, Wiring, Bracket, Common Release Pressure (PD) Port Size, Manifold Individual Supply, Manifold Assembly (Delivery Condition), Vacuum unit variation, Configuration, Specifications, Manifold connection type, Special environment, the required quantity and your application notes with Pnoneks. Final compatibility and lead time are confirmed during quotation.

ABOUT THE PRODUCT

The essentials for selection.

Manufacturer
SMC
Series
ZK2*A
Product group
Vacuum technology
Function
Vacuum Ejectors
Applications
Suitability is evaluated against technical specifications and application conditions.
Selection parameters
Stations, System/Port, Exhaust, Wiring, Bracket, Common Release Pressure (PD) Port Size, Manifold Individual Supply, Manifold Assembly (Delivery Condition), Vacuum unit variation, Configuration, Specifications, Manifold connection type, Special environment

Exact dimensions, operating ranges and compatibility depend on the full part number. Review the relevant SMC documentation and application conditions for technical selection.

TECHNICAL PRODUCT INFORMATION

Features and model options

Technical descriptions and values below are preserved in the manufacturer’s original language. Options describe alternatives within the series; not every combination is valid. We will verify the full part number when quoting.

The all-in-one silent energy saving solution

  • Achieve efficiency – Ejector, pump and manifold system in a single unit
  • Lower your air consumption – Energy saving digital vacuum switch and a 2-stage ejector
  • Get compactness and lightness – Ideal solution for moving tools
  • Communicate remotely – Control and monitor up to 16 outputs via a wide variety of serial interface communication protocols and IO-Link.

And much more

  • Advanced vacuum unit (ejector/pump/manifold systems) with low noise and high efficiency options.
  • Energy saving digital vacuum switch: Intermittent energizing (supply/exhaust) only when vacuum decreases.
  • More efficient 2-stage ejector: Air consumption 30 % reduced.
  • Dual 2 port valve (release valve/supply valve): Can hold vacuum even when the power goes out or is turned off. Prevents the sudden dropping of workpieces.
  • All-in-one design with integrated components to make it compact and lightweight.
  • Control and monitor up to 32 outputs via a wide variety of serial interface communication protocols:
  • EX260 Compatible protocols: IO-Link, DeviceNet, PROFIBUS DP, CC-Link, EtherNet/IP™, EtherCAT ®, PROFINET, Ethernet POWERLINK
  • EX500 Compatible protocols: Getaway decentralised system
  • EX600 Compatible protocols: DeviceNet, PROFIBUS DP, CC-Link, EtherNet/IP™, EtherCAT ®, PROFINET, wireless, compatible wireless base.
  • Available variations for non-standard environments: secondary batteries manufacturing
  • Air operated.
Selection fields published in the source
ParameterOptions / values
Stations01 (1 Station) · 02 (2 Stations) · 03 (3 Stations) · 04 (4 Stations) · 05 (5 Stations) · 06 (6 Stations) · 07 (7 Stations) · 08 (8 Stations) · 09 (9 Stations) · 10 (10 Stations)
System/PortA [Ejector system / ø8 (Common PV)] · AN [Ejector system / ø5/16 (Common PV)]
Exhaust1 (Complex Exhaust) · 2 (Individual Exhaust)
WiringL (Individual Wiring) · F (D-sub Connector) · P (Flat Ribbon Cable Connector) · N [No Wiring (No Valve)]
BracketNone · B (With DIN Rail Mounting Bracket)
Common Release Pressure (PD) Port SizeNone · D (Common Release Pressure Supply)
Manifold Individual SupplyNone · L (Manifold Individual Supply Spec.)
Manifold Assembly (Delivery Condition)Individual Units Assembled Delivered as a Manifold · A [Delivered as Individual Parts (not assembled)]
Vacuum unit variationEjector system · Vacuum pump system
ConfigurationSingle unit for individual mounting · Single unit for individual mounting (IO-Link) · Single unit for mounting in manifold · Single unit for mounting in manifold (IO-Link) · Manifold
SpecificationsElectrically operated (Supply valve: N.C. / Self-holding) · Electrically operated (Supply valve: N.O.) · Air operated (Supply valve: N.C.)
Manifold connection typeNone · Individual wiring · D-sub Connector · Flat ribbon cable · Serial trasmision system EX260 · Serial trasmision system EX500 · Serial trasmision system EX600
Special environmentNot required · Battery Manufacturing
Let’s find your solution