SMC Authorized Reseller
Monday–Friday · 09:00–18:000850 811 86 07
SMCZK2*00 ZK2*00, Vacuum Unit, Vacuum Pump SystemSeries image. Appearance may vary by model and options.
Vacuum technology

ZK2*00

ZK2*00, Vacuum Unit, Vacuum Pump System

Explore the features, model options and technical documentation for ZK2*00. Contact Pnoneks to select the full part number for your application.

SMC ·Vacuum Ejectors

Request a quote for your application.

Share your part number and quantity so we can confirm pricing and lead time.

Your message opens in WhatsApp. You can review and edit it before sending.

Selecting ZK2*00

Selecting ZK2*00: review the full part number and your system conditions when considering this Vacuum technology record. Share Body Type, Supply Valve / Release Valve, Rated Voltage, Pressure Sensor/Digital Pressure Switch for Vacuum Spec., Supply Valve/Release Valve/Digital Pressure Switch for Vacuum Connector Spec., Vacuum (V) Port, Bracket, Pump System PE Port Female Thread, Individual Release Pressure Supply, Vacuum Break Flow Adjusting Unit, Manifold Common Release Pressure Supply, the required quantity and your application notes with Pnoneks. Final compatibility and lead time are confirmed during quotation.

ABOUT THE PRODUCT

The essentials for selection.

Manufacturer
SMC
Series
ZK2*00
Product group
Vacuum technology
Function
Vacuum Ejectors
Applications
Suitability is evaluated against technical specifications and application conditions.
Selection parameters
Body Type, Supply Valve / Release Valve, Rated Voltage, Pressure Sensor/Digital Pressure Switch for Vacuum Spec., Supply Valve/Release Valve/Digital Pressure Switch for Vacuum Connector Spec., Vacuum (V) Port, Bracket, Pump System PE Port Female Thread, Individual Release Pressure Supply, Vacuum Break Flow Adjusting Unit, Manifold Common Release Pressure Supply

Exact dimensions, operating ranges and compatibility depend on the full part number. Review the relevant SMC documentation and application conditions for technical selection.

TECHNICAL PRODUCT INFORMATION

Features and model options

Technical descriptions and values below are preserved in the manufacturer’s original language. Options describe alternatives within the series; not every combination is valid. We will verify the full part number when quoting.

  • This product is being discontinued and will be replaced by ZK2-A series. Update details here .
  • Vacuum Pump System.
  • More efficient 2-stage ejector.
  • Dual 2 port valve (Release valve/Supply valve).
  • All in one design with integrated components.
  • Easy maintenance.
  • Mounting variations.
  • Pressure sensor / switches variations.
Selection fields published in the source
ParameterOptions / values
Body TypeP (Single Unit) · Q (For Manifold)
Supply Valve / Release ValveK (N.C. / N.C.) · J (N.C. / None) · R (Self-holding Release Valve Linked / N.C.)
Rated Voltage5 (24 VDC) · 6 (12 VDC)
Pressure Sensor/Digital Pressure Switch for Vacuum Spec.P (Pressure Sensor / 0 to -101 kPa / Analogue Output 1 to 5 V) · T (Pressure Sensor / -100 to 100 kPa / Analogue Output 1 to 5 V) · A (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs / Unit Selection Function) · B (Digital Pressure Switch for Vacuum / 0 to -101 kPa / NPN 2 Outputs / SI Unit only) · C (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs / Unit Selection Function) · D (Digital Pressure Switch for Vacuum / 0 to -101 kPa / PNP 2 Outputs / SI Unit only) · E (Digital Pressure Switch for Vacuum / -100 to 100 kPa / NPN 2 Outputs / Unit Selection Function) · F (Digital Pressure Switch for Vacuum / -100 to 100 kPa / NPN 2 Outputs / SI Unit only) · H (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs / Unit Selection Function) · J (Digital Pressure Switch for Vacuum / -100 to 100 kPa / PNP 2 Outputs / SI Unit only) · N (Without Pressure Sensor / Digital Pressure Switch for Vacuum)
Supply Valve/Release Valve/Digital Pressure Switch for Vacuum Connector Spec.C [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor] · C1 [Common Wiring (plug-in) - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor] · L [L-type Plug Connector - w/ Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor] · L1 [L-type Plug Connector - w/o Lead Wire with Connector - w/ Lead Wire with Connector for Pressure Switch/sensor] · L2 [L-type Plug Connector - w/ Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor] · L3 [L-type Plug Connector - w/o Lead Wire with Connector - w/o Lead Wire with Connector for Pressure Switch/sensor]
Vacuum (V) Port06 [ø6 One-touch Fitting (Metric)] · 08 [ø8 One-touch Fitting (Metric)] · 07 [ø1/4 One-touch Fitting (Inch)] · 09 [ø5/16 One-touch Fitting (Inch)]
BracketNone · B [With One Bracket for Mounting a Single Unit (Mounting Screw is Attached)]
Pump System PE Port Female ThreadNone · C (with Pump System PE Port Female Thread)
Individual Release Pressure SupplyNone · D [With Individual Release Pressure Supply (PD) Port Type]
Vacuum Break Flow Adjusting UnitNone · J (Vacuum Break Flow Adjustment Needle Round Lock Nut Type) · K (Vacuum Break Flow Adjustment Needle Screwdriver Operation Type)
Manifold Common Release Pressure SupplyNone · P (Manifold Common Release Pressure Supply Spec.)
Let’s find your solution